Line 56: Line 56:
  
 {{:dsc03142_1_.jpg|}}\\ {{:dsc03142_1_.jpg|}}\\
 +
 Note the angle iron PV module support rails that are Note the angle iron PV module support rails that are
-welded to the 1.5 inch pipe mounts.+welded to the 1.5 inch pipe mounts.\\ 
 {{:dsc03164.jpg|}}\\ {{:dsc03164.jpg|}}\\
 +
 Closer view of the PV module angle iron support rails. Closer view of the PV module angle iron support rails.
 Note the stainless steel attachment of PV modules to the  Note the stainless steel attachment of PV modules to the 
-angle iron rails.+angle iron rails.\\ 
 ==== Array Side Wiring ==== ==== Array Side Wiring ====
  
Line 91: Line 95:
 Trenching for the wire from PV array to the house.\\ Trenching for the wire from PV array to the house.\\
  
-House Side Wiring+==== House Side Wiring ====
  
 The TVA requires what is referred to as a line or supply side connection, which means that the solar feed connects to the grid at their usage meter. Many parts of the country use what is called a load side connection. This would require running the cables from the solar array into the house breaker panel. Line side was much easier for me. I had to buy a meter base for the solar supply meter, and a manual disconnect switch. The wiring from the array runs through the buried conduit into the solar supply meter; into the manual disconnect switch, and then over to the usage meter. All boxes were connected with grounds and to a ground rod. The TVA requires what is referred to as a line or supply side connection, which means that the solar feed connects to the grid at their usage meter. Many parts of the country use what is called a load side connection. This would require running the cables from the solar array into the house breaker panel. Line side was much easier for me. I had to buy a meter base for the solar supply meter, and a manual disconnect switch. The wiring from the array runs through the buried conduit into the solar supply meter; into the manual disconnect switch, and then over to the usage meter. All boxes were connected with grounds and to a ground rod.
Line 109: Line 113:
 When the connection day finally came, it was cold, snowing, windy and completely overcast, yet the system put out enough power to successfully complete the test. When the connection day finally came, it was cold, snowing, windy and completely overcast, yet the system put out enough power to successfully complete the test.
  
-{{:dsc03141.jpg|}}+{{:dsc03141.jpg|}}\\ 
 + 
 +The PV array disconnect at the house. 
 +This completely disconnects the PV array from the utility power.\\ 
 {{:house_cut_off.jpg|}}\\ {{:house_cut_off.jpg|}}\\
  
-With the Enphase Enlighten monitoring system, anyone can go to  My Enphase Web Page  and see current and historical production. As of this writing, it's only been connected for a month of short and often cloudy winter weather. Even so, it is averaging just a little under our usage. I feel confident the longer sunny days of summer will create more power than we are using.+Inside the PV array disconnect.\\
  
 +With the Enphase Enlighten monitoring system, anyone can go to  My Enphase Web Page  and see current and historical production. As of this writing, it's only been connected for a month of short and often cloudy winter weather. Even so, it is averaging just a little under our usage. I feel confident the longer sunny days of summer will create more power than we are using.
  
  
dougs_4.6kw_diy_grid_tied_array.1351430726.txt.gz · Last modified: 2012/10/28 09:25 by tomgee