Line 4: Line 4:
   * Pressure switch closes when motor starts.   * Pressure switch closes when motor starts.
  
-  * 1. Locate the Pressure Switch on the back side of the stainless steel Heater Housing. The gray cable from the switch is connected to J3 (Platinum or Primer/Select) or J9 (Duplex).+  Locate the Pressure Switch on the back side of the stainless steel Heater Housing. The gray cable from the switch is connected to J3 (Platinum or Primer/Select) or J9 (Duplex).
   -  Unplug the pressure switch from the circuit board and with a paperclip or pin knife, push out the two pins from the connector. Clip the leads from an OHM-METER onto these two pins.   -  Unplug the pressure switch from the circuit board and with a paperclip or pin knife, push out the two pins from the connector. Clip the leads from an OHM-METER onto these two pins.
   - With the system "OFF" and no voltage to the Pump/Motor the reading of the OHM-METER should be on "OPEN". If the meter shows the switch as being "CLOSED" adjust the spoked wheel on thenpressure switch counter-clockwise until an "OPEN" condition is read on the OHM-METER.   - With the system "OFF" and no voltage to the Pump/Motor the reading of the OHM-METER should be on "OPEN". If the meter shows the switch as being "CLOSED" adjust the spoked wheel on thenpressure switch counter-clockwise until an "OPEN" condition is read on the OHM-METER.