Jacuzzi Pressure Switch notes

  1. Locate the Pressure Switch on the back side of the stainless steel Heater Housing. The gray cable from the switch is connected to J3 (Platinum or Primer/Select) or J9 (Duplex).
  2. Unplug the pressure switch from the circuit board and with a paperclip or pin knife, push out the two pins from the connector. Clip the leads from an OHM-METER onto these two pins.
  3. With the system “OFF” and no voltage to the Pump/Motor the reading of the OHM-METER should be on “OPEN”. If the meter shows the switch as being “CLOSED” adjust the spoked wheel on thenpressure switch counter-clockwise until an “OPEN” condition is read on the OHM-METER.
  4. Start the Spa operation in a “Filter” mode and check the OHM-METER reading for a “CLOSED” switch reading. If the reading shows the switch to be in an “OPEN”, turn the spoked wheel on the pressure switch clockwise until the meter reads “CLOSED” plus a little further to allow for a dirty filter.
  5. Repeat Step #3. The OHM-METER should read “OPEN” with no power to pump/motor. NOTE: Be sure all these adjustments are done in the low “Filter” mode and not the high-speed “Jet” operation. The pump/motor connection can be disconnected by unplugging the side motor connector while testing steps #3 and #4.