User Tools

Site Tools


info:misc:jacuzzi_pressure_switch_notes

This is an old revision of the document!


Jacuzzi Pressure Switch notes

  • Pressure switch is normally open without motor running.
  • Pressure switch closes when motor starts.
  • 1. Locate the Pressure Switch on the back side of the stainless steel Heater Housing. The gray cable

from the switch is connected to J3 (Platinum or Primer/Select) or J9 (Duplex).

  1. Unplug the pressure switch from the circuit board and with a paperclip or pin knife, push out the

two pins from the connector. Clip the leads from an OHM-METER onto these two pins.

  1. With the system “OFF” and no voltage to the Pump/Motor the reading of the OHM-METER should

be on “OPEN”. If the meter shows the switch as being “CLOSED” adjust the spoked wheel on the pressure switch counter-clockwise until an “OPEN” condition is read on the OHM-METER.

  1. Start the Spa operation in a “Filter” mode and check the OHM-METER reading for a “CLOSED”

switch reading. If the reading shows the switch to be in an “OPEN”, turn the spoked wheel on the pressure switch clockwise until the meter reads “CLOSED” plus a little further to allow for a dirty filter.

  1. Repeat Step #3. The OHM-METER should read “OPEN” with no power to pump/motor. NOTE: Be

sure all these adjustments are done in the low “Filter” mode and not the high-speed “Jet” operation. The pump/motor connection can be disconnected by unplugging the side motor connector while testing steps #3 and #4.

info/misc/jacuzzi_pressure_switch_notes.1499198886.txt.gz · Last modified: 2017/07/04 16:08 by tomgle